Inspection, Ultrasonic, Product Over 0.5 Inch (12.7 mm) Thick

Standard:
Revised:
  • 2010-01-05
 
  • CURRENT
Publisher:
  • SAE International
Pages:
21
Scope:

This specification covers procedures for ultrasonic inspection, by pulse-echo procedures, of flat, rectangular, round, cylindrical, and contoured products having a thickness or cross-sectional dimension greater than 0.50 inch (12.7 mm), using either contact or immersion methods, and using the longitudinal-wave or shear-wave modes or combinations of the two, as necessary. This specification may apply to testing finished machined parts provided the parts can meet the basic testability requirements, such as size, contour, metallurgical structure, and thickness.

Rationale:

AMS2630C revises requirements for qualification (3.1.1), transducers (3.2.2.1), shear wave references (3.2.4.4), special references (3.2.4.6), and gating (3.4.9.1.2), and is a Five Year Review and update of this specification.